ارسل ملاحظاتك

ارسل ملاحظاتك لنا







Study of Ethanol Analysis in Blood by Headspace / Gas Chromatography / Flame Ionization Detector for Ensuring Validation

المصدر: مجلة إدارة الجودة الشاملة
الناشر: جامعة السودان للعلوم والتكنولوجيا
المؤلف الرئيسي: Hamza, Ahmed Mubarak Ahmed (Author)
مؤلفين آخرين: Saeed, Ahmed Elsadig Mohamed (Co-Author)
المجلد/العدد: مج21, ع1
محكمة: نعم
الدولة: السودان
التاريخ الميلادي: 2020
الصفحات: 85 - 92
ISSN: 1605-427x
رقم MD: 1089586
نوع المحتوى: بحوث ومقالات
اللغة: الإنجليزية
قواعد المعلومات: EcoLink
مواضيع:
كلمات المؤلف المفتاحية:
Reference Material | Internal Standard | Quality Control | Etoh | Ethanol
رابط المحتوى:
صورة الغلاف QR قانون

عدد مرات التحميل

5

حفظ في:
LEADER 04256nam a22002417a 4500
001 1830405
041 |a eng 
044 |b السودان 
100 |9 567922  |a Hamza, Ahmed Mubarak Ahmed  |e Author 
245 |a Study of Ethanol Analysis in Blood by Headspace / Gas Chromatography / Flame Ionization Detector for Ensuring Validation 
260 |b جامعة السودان للعلوم والتكنولوجيا  |c 2020 
300 |a 85 - 92 
336 |a بحوث ومقالات  |b Article 
520 |a تأكيد صحة نتائج المعمل يعتبر من أهم متطلبات كفاءة إجراء الفحص. النتائج التي يصدرها المعمل يجب أن تفي بقدر ما كان ذلك ممكنا جودة القياسات، حالة من التأكيد مقابلة متطلبات المواصفة. لذا يجب على مختبرات الفحص أن تنشئ إجراء يعنى بمراقبة وتأكيد صحة نتائجه. تم وضع إجراء لتأكيد صحة النتائج التي يقدمها المختبر كما هو مطلوب أو ما يعتبر مناسبا لمراقبة صحة الاختبارات التي يجريها. تم تعريف الأنشطة المطلوبة للوفاء بمتطلبات التحقق من صحة النتائج بناء على طريقة التحليل، تحليل، تقييم، مراقبة ومراجعة. لتأكيد صحة نتائج البيانات الناتجة عن اختبار تحليل الكحول الإيثيلى في الدم باستخدام جهاز - Headspace/GC/FID تم استخدام الأساليب الإحصائية، النوعية، اختيار الطريقة، العلاقة الخطية، المدى المطلوب، المرجعات البينية لأجهزة القياس، دقة البيانات ودقة النتائج مستخدمين للمواد العيارية والمرجعية. أهمية الدراسة في كونها تساعد المحلل لتثبيت أعلي مستويات أداء، تقلل من اختلاف نتائج الفحص، تحسين مصداقية نتائج الفحص وإمكانية تحويل البيانات إلى أجوبة لها علاقة مباشرة بمشكلة الذبون. 
520 |b Ensuring the validity of laboratory results is one of the general requirements for the competence to carry out tests. The results provided by the laboratory should be satisfied as far as possible/where relevant with the quality of the measurements, statement of conformity with standard requirements or specifications. A laboratory performing testing should have a procedure for monitoring the validity of its results. To ensure the validity of laboratory results as required or deemed appropriate for monitoring laboratory performance, a procedure for monitoring the validity of results was established. The activities that are required to fulfil validity of results based on analytical method performance characteristics were identified, analyzed, evaluated, monitored and reviewed. To assure the validity of the results, statistical techniques were applied to the monitoring and reviewing of the performance characteristics resulting data. Specificity, selectivity, linearity, acceptance limits, intermediate checks on measuring equipment, precision and accuracy, of the developed method (Ethanol analysis in blood by Headspace/GC/FID) were monitored using reference materials and positive blood control sample. The present study, assist the analyst to maintain a high level of test performance, reduces variation in test results, improves the confidence of testing results, able to translate the data into answers, which directly relate to solving the customer’s problem. 
653 |a مختبرات الفحص  |a إدارة الجودة الشاملة  |a صحة الاختبارات 
692 |b Reference Material  |b Internal Standard  |b Quality Control  |b Etoh  |b Ethanol 
700 |9 567921  |a Saeed, Ahmed Elsadig Mohamed  |e Co-Author 
773 |4 الإدارة  |6 Management  |c 007  |e Total Qualaity Management Journal  |l 001  |m مج21, ع1  |o 1492  |s مجلة إدارة الجودة الشاملة  |v 021  |x 1605-427x 
856 |u 1492-021-001-007.pdf 
930 |d y  |p y  |q n 
995 |a EcoLink 
999 |c 1089586  |d 1089586