ارسل ملاحظاتك

ارسل ملاحظاتك لنا







Effect of Disinfection with Hypochlorous Acid on Compatibility with Impression Materials of Type III Dental Stone

المصدر: مجلة ميسان للدراسات الأكاديمية
الناشر: جامعة ميسان - كلية التربية الأساسية
المؤلف الرئيسي: Nasser, Ann A. (Author)
مؤلفين آخرين: Abass, Shorouq M. (Co-Author)
المجلد/العدد: مج22, ع47
محكمة: نعم
الدولة: العراق
التاريخ الميلادي: 2023
الشهر: أيلول
الصفحات: 339 - 347
DOI: 10.54633/2333-022-047-022
ISSN: 1994-697X
رقم MD: 1414689
نوع المحتوى: بحوث ومقالات
اللغة: الإنجليزية
قواعد المعلومات: EduSearch, HumanIndex
مواضيع:
كلمات المؤلف المفتاحية:
Dental Stone | Hypochlorous Acid | Compatibility with Impression Materials | Fourier Transmission Infrared Spectroscopy
رابط المحتوى:
صورة الغلاف QR قانون

عدد مرات التحميل

2

حفظ في:
LEADER 02687nam a22002537a 4500
001 2163307
024 |3 10.54633/2333-022-047-022 
041 |a eng 
044 |b العراق 
100 |9 748392  |a Nasser, Ann A.  |e Author 
245 |a Effect of Disinfection with Hypochlorous Acid on Compatibility with Impression Materials of Type III Dental Stone 
260 |b جامعة ميسان - كلية التربية الأساسية  |c 2023  |g أيلول 
300 |a 339 - 347 
336 |a بحوث ومقالات  |b Article 
520 |b Background: In dentistry, dental stone are utilized to create casts for various dental laboratory procedures. Since it comes into contact with the saliva and blood observed on dental impressions, it is regarded as an origin of contamination. Disinfection of the cast has become crucial to preventing infections. Aim: To determine how type III dental stone's compatibility with the impression materials will be affected by adding a disinfectant (hypochlorous acid (HOCl)) as a water replacement. Methods: A total of 90 specimens of type III dental stone were prepared and separated into three groups, ten specimens for each test group, including group A (control), group B (incorporation of 60 ppm HOCl), and group C (incorporation of 100 ppm HOCl). There were 30 specimens for each type of impression material, including alginate, addition silicone, and zinc oxide eugenol. The specimens of compatibility with the impression material of type III dental stone were evaluated using an optical microscope (Dino Lite, Taiwan). Results: The results presented that all specimens passed the compatibility with the impression materials test after adding HOCl, which received a score of I. Conclusion: Since type III gypsum products tested for compatibility with impression materials are unaffected by the addition of a hypochlorous acid disinfection solution, this is encouraging. 
653 |a المطهرات الطبية  |a حمض الهيبوكلوروس  |a حجر الأسنان 
692 |b Dental Stone  |b Hypochlorous Acid  |b Compatibility with Impression Materials  |b Fourier Transmission Infrared Spectroscopy 
700 |9 748402  |a Abass, Shorouq M.  |e Co-Author 
773 |4 التربية والتعليم  |4 العلوم الإنسانية ، متعددة التخصصات  |6 Education & Educational Research  |6 Humanities, Multidisciplinary  |c 022  |e Maisan Journal of Academic Studies  |f Maǧallaẗ Mīsān li-l-dirāsāt al-akādīmiyyaẗ  |l 047  |m مج22, ع47  |o 2333  |s مجلة ميسان للدراسات الأكاديمية  |v 022  |x 1994-697X 
856 |u 2333-022-047-022.pdf 
930 |d y  |p y  |q y 
995 |a EduSearch 
995 |a HumanIndex 
999 |c 1414689  |d 1414689