ارسل ملاحظاتك

ارسل ملاحظاتك لنا







Optimization of Horizontal Wells by Using down Hole Inflow Control Devices

المصدر: المجلة العربية للنشر العلمي
الناشر: مركز البحث وتطوير الموارد البشرية - رماح
المؤلف الرئيسي: Abdurrahman, G. (Author)
مؤلفين آخرين: Eljareh, S. (Co-Author)
المجلد/العدد: ع24
محكمة: نعم
الدولة: الأردن
التاريخ الميلادي: 2020
الشهر: تشرين الأول
الصفحات: 15 - 28
ISSN: 2663-5798
رقم MD: 1436941
نوع المحتوى: بحوث ومقالات
اللغة: الإنجليزية
قواعد المعلومات: EduSearch, HumanIndex
مواضيع:
كلمات المؤلف المفتاحية:
Inflow Control Devices | Horizontal Wells
رابط المحتوى:
صورة الغلاف QR قانون
حفظ في:
LEADER 02442nam a22002417a 4500
001 2183878
041 |a eng 
044 |b الأردن 
100 |9 757859  |a Abdurrahman, G.  |e Author 
245 |a Optimization of Horizontal Wells by Using down Hole Inflow Control Devices 
260 |b مركز البحث وتطوير الموارد البشرية - رماح  |c 2020  |g تشرين الأول 
300 |a 15 - 28 
336 |a بحوث ومقالات  |b Article 
520 |b Oil production currently has challenges such as excessive water production, which reduces the cumulative oil recovery, this occurs due to water coning in the reservoir which resulted to earlier water breakthrough in the wellbore. Various Down hole Flow control Devices (DFCs) including ICDs, AICDs, and AICVS are typically installed in the horizontal section of oil wells to mitigate the problem. The study of autonomous ICDs was done by comparing the long term flow performance of such devices against passive ICDs. The study was carried out with a reservoir model representing one horizontal well (X2) with three completion alternatives: open hole, ICD and AICDs which were perforating in numerical reservoir model, the model and completion was built and designed by (Petrel 2016) software; these cases were run in the Eclipse simulator and their results were compared with the open hole. The installation of DFCs (ICDs, and AICDs) in the horizontal well increased the oil recovery (RF) significantly, however the installation of Autonomous ICDs (AICDs) in the horizontal well perforating the oil reservoir increased more oil when compared against the passive ICDs, and this had been proved by the results of the reservoir model. 
653 |a الآبار النفطية  |a المواد البترولية  |a أجهزة التحكم بالتدفق 
692 |b Inflow Control Devices  |b Horizontal Wells 
700 |9 757860  |a Eljareh, S.  |e Co-Author 
773 |4 العلوم الإنسانية ، متعددة التخصصات  |4 العلوم الاجتماعية ، متعددة التخصصات  |6 Humanities, Multidisciplinary  |6 Social Sciences, Interdisciplinary  |c 002  |e Arab journal for scientific publishing  |f al-Mağallaẗ al-ʿarabiyyaẗ li-l-našr al-ilmī  |l 024  |m ع24  |o 2502  |s المجلة العربية للنشر العلمي  |v 000  |x 2663-5798 
856 |u 2502-000-024-002.pdf 
930 |d y  |p y  |q n 
995 |a EduSearch 
995 |a HumanIndex 
999 |c 1436941  |d 1436941 

عناصر مشابهة