ارسل ملاحظاتك

ارسل ملاحظاتك لنا







Exploiting Geothermal Energy as a Source of Heating System in Al-Shaydia Phosphate Mining: Overview and Case Study

المصدر: مجلة جامعة الحسين بن طلال للبحوث
الناشر: جامعة الحسين بن طلال - عمادة البحث العلمي والدراسات العليا
المؤلف الرئيسي: Al-Maasfeh, Sohaib I. (Author)
مؤلفين آخرين: Behiri, Mohamed Ramadan Gomaa (Co-Author) , Azetawi, Ayoub (Co-Author) , Shwakih, Adnan (Co-Author) , Mehdawi, Mohammad (Co-Author)
المجلد/العدد: مج9, ع4
محكمة: نعم
الدولة: الأردن
التاريخ الميلادي: 2023
الصفحات: 57 - 77
DOI: 10.36621/0397-009-004-003
ISSN: 2519-7436
رقم MD: 1444352
نوع المحتوى: بحوث ومقالات
اللغة: الإنجليزية
قواعد المعلومات: EduSearch, AraBase, HumanIndex
مواضيع:
كلمات المؤلف المفتاحية:
Geothermal | Energy Saving | Heating System | Heat Pump | Power Generation
رابط المحتوى:
صورة الغلاف QR قانون
حفظ في:
LEADER 02976nam a22003017a 4500
001 2190466
024 |3 10.36621/0397-009-004-003 
041 |a eng 
044 |b الأردن 
100 |9 765432  |a Al-Maasfeh, Sohaib I.  |e Author 
245 |a Exploiting Geothermal Energy as a Source of Heating System in Al-Shaydia Phosphate Mining:  |b Overview and Case Study 
260 |b جامعة الحسين بن طلال - عمادة البحث العلمي والدراسات العليا  |c 2023 
300 |a 57 - 77 
336 |a بحوث ومقالات  |b Article 
520 |b Nowadays, energy is the primary input for all economic activities. It plays a significant role in raising the standard of living, which has become the ultimate goal of most communities. This natural energy can be produced from the earth's heat, used for heating, and cooling buildings, generating electricity, and providing warm/cold water for agricultural items in greenhouses. Jordan's NE and SE deserts have geothermal resources. Based on that, the researcher developed a project that uses hot water from the Shaydia mine to heat the buildings. Talking about If geothermal power is used, then the cost of the heat exchanger should be saved. Thermal loads and mass flow rates were calculated manually to determine the size of the system. The cost of the project has been calculated by ordering all parts and pipelines from many companies, comparing their prices, and testing with their average prices. This paper shows how to control mass flow rate for all apartments by varying convection heat transfer coefficient with outdoor and indoor temperatures. The heat load is 3828 kW, so 82.08 m3/h of flow is needed to cover all residential structures and 0.33 L/h of chemical treatment before water enters the network. After calculating the costs of the current system and comparing them to the costs of the project to see if it is possible or not, it's found that it is possible and very available to the company, which will bring in about $300,000 per year. 
653 |a موارد الطاقة  |a الطاقة الحرارية  |a مناجم الفوسفات  |a توليد الطاقة 
692 |b Geothermal  |b Energy Saving  |b Heating System  |b Heat Pump  |b Power Generation 
700 |9 513245  |a Behiri, Mohamed Ramadan Gomaa  |e Co-Author 
700 |9 765436  |a Azetawi, Ayoub  |e Co-Author 
700 |9 765437  |a Shwakih, Adnan  |e Co-Author 
700 |9 765439  |a Mehdawi, Mohammad  |e Co-Author 
773 |4 العلوم الإنسانية ، متعددة التخصصات  |4 علم الإجتماع  |6 Humanities, Multidisciplinary  |6 Sociology  |c 003  |f Mağallaẗ Ğāmiʿaẗ al-Ḥusayn bin Ṭalāl li-l-buḥūṯ  |l 004  |m مج9, ع4  |o 0397  |s مجلة جامعة الحسين بن طلال للبحوث  |t Al - Hussein Bin Talal University Journal of Research  |v 009  |x 2519-7436 
856 |u 0397-009-004-003.pdf 
930 |d y  |p y  |q n 
995 |a EduSearch 
995 |a AraBase 
995 |a HumanIndex 
999 |c 1444352  |d 1444352 