ارسل ملاحظاتك

ارسل ملاحظاتك لنا







Determination of Benzene , Toluene, Ethylbenzene and Xylenes (BTEX) in Produced Water by Solid Phase Microextraction with Gas Chromatography Flame Ionization Detector (GC-FID)

المصدر: المؤتمر الثاني لعلوم البيئة
الناشر: الجامعة الأسمرية للعلوم الإسلامية زليتن - كلية الموارد البحرية
المؤلف الرئيسي: Omar, Salem A. S. (Author)
محكمة: نعم
الدولة: ليبيا
التاريخ الميلادي: 2015
مكان انعقاد المؤتمر: زليتن - ليبيا
رقم المؤتمر: الثاني
الهيئة المسؤولة: الجامعة الأسمرية للعلوم الإسلامية. كلية الموارد البحرية
الشهر: ديسمبر
الصفحات: 490 - 502
رقم MD: 765726
نوع المحتوى: بحوث المؤتمرات
قواعد المعلومات: IslamicInfo, HumanIndex
مواضيع:
رابط المحتوى:
صورة الغلاف QR قانون

عدد مرات التحميل

8

حفظ في:
LEADER 02185nam a22002297a 4500
001 0145681
044 |b ليبيا 
100 |9 403993  |a Omar, Salem A. S.  |e Author 
245 |a Determination of Benzene , Toluene, Ethylbenzene and Xylenes (BTEX) in Produced Water by Solid Phase Microextraction with Gas Chromatography Flame Ionization Detector (GC-FID) 
260 |b الجامعة الأسمرية للعلوم الإسلامية زليتن - كلية الموارد البحرية  |c 2015  |g ديسمبر 
300 |a 490 - 502 
336 |a بحوث المؤتمرات 
520 |b During the production of crude oil and gas, large amounts of produced water are generated. These waters have to be analyzed with relation to the chemical composition to figure out the environmental impact of its discharge. Therefore, a study was carried out to evaluate concentration of the BTEX (benzene, toluene, ethylbenzene and xylenes), in produced water samples taken from production facilities and the disposal pit at the oilfield, Libya. SPME with Gas Chromatography Flame Ionization Detector (GC-FID) methods was optimized to determine the target compounds. The results showed that concentrations of the target compounds in the produced water samples ranged from 0.13 to 1.86 ppm. In addition, BTEX values are much higher, (1.86 and 1.70 mg/l), at storage tank outlet (TA,) and discharged stream (pump) respectively, where the produced water is in the earlier steps, before discharging to the pits. In the pit samples (Spt1, Spt2, Spt3 and Spt4) the BTEX values range between 0.11 to 0.22 mg/l. In general, produced water sample taking from the disposal pit contained lower BTEX concentrations than those from the production facilities.  
653 |a ليبيا 
653 |a تلوث المياة 
653 |a التلوث البيئي 
773 |c 038  |d زليتن - ليبيا  |i الجامعة الأسمرية للعلوم الإسلامية. كلية الموارد البحرية  |l 000  |o 7223  |p الثاني  |s المؤتمر الثاني لعلوم البيئة  |v 000 
856 |u 7223-000-000-038.pdf 
930 |d y  |p y 
995 |a IslamicInfo 
995 |a HumanIndex 
999 |c 765726  |d 765726