ارسل ملاحظاتك

ارسل ملاحظاتك لنا









Plasma Needles on the Teeth Structure and Compressibility

المصدر: المجلة العربية للعلوم ونشر الأبحاث
الناشر: المركز القومي للبحوث بغزة
المؤلف الرئيسي: Hussein, Mohammed U. (Author)
المجلد/العدد: مج2, ع4‪
محكمة: نعم
الدولة: فلسطين
التاريخ الميلادي: 2016
الشهر: مايو‪
الصفحات: 46 - 50
DOI: 10.12816/0025163
ISSN: 2518-5780
رقم MD: 777035
نوع المحتوى: بحوث ومقالات
اللغة: الإنجليزية
قواعد المعلومات: HumanIndex
مواضيع:
كلمات المؤلف المفتاحية:
teeth | plasma needle | strain | necrosis
رابط المحتوى:
صورة الغلاف QR قانون

عدد مرات التحميل

24

حفظ في:
LEADER 02595nam a22002297a 4500
001 0156579
024 |3 10.12816/0025163 
041 |a eng 
044 |b فلسطين 
100 |9 411348  |a Hussein, Mohammed U.  |e Author 
245 |a Plasma Needles on the Teeth Structure and Compressibility 
260 |b المركز القومي للبحوث بغزة  |c 2016  |g مايو‪ 
300 |a 46 - 50 
336 |a بحوث ومقالات  |b Article 
520 |b The aim from this research is to prove not affected the teeth of both damage macroscopic and the internal structure of teeth (compressibility). The teeth were collected from (Al karama dental specialized) in Baghdad, directly after uprooted from the patient's mouth. It was in table by the material (normal saline, sodium chloride, 0.9%), according to instructions of dental disease specialist. It was regarded as a natural model replica. It has been conducted two tests on some samples: studying the macroscopic damage for teeth and studying the influence compressibility for teeth. The design of generation argon plasma needle system, this system works on production Non- thermal plasma at atmospheric pressure, where used simples electronics constructions and cost low, it has power to generate high electric field on electrodes enough to ionize different gases and flow in atmospheric pressure. The device jet plasma needle used surely from no events any macroscopic or mechanical damage in build inside teeth (compressibility) ,where it applied on some teeth sample at time double treatment time ,then teeth check consequently favorableness result ,where load force of tooth without plasma exposure was 1.74kN while load force of tooth with plasma exposure was 1.824kN.Studying the macroscopic damage for teeth, the mentioned area were not affected with damage or change colors, therefore in effecting the teeth with any negative results during plasma needle process. 
653 |a الأسنان‪  |a البلازما‪ 
692 |b teeth  |b plasma needle  |b strain  |b necrosis 
773 |4 العلوم الإنسانية ، متعددة التخصصات  |4 العلوم الاجتماعية ، متعددة التخصصات  |6 Humanities, Multidisciplinary  |6 Social Sciences, Interdisciplinary  |c 005  |e Arab Journal of Sciences and Research Publishing  |f Al-Mağallaẗ al-ʿarabiyyaẗ li-l-ʿulūm wa-našr abḥāṯ  |l 004  |m مج2, ع4‪  |o 1564  |s المجلة العربية للعلوم ونشر الأبحاث  |v 002  |x 2518-5780 
856 |u 1564-002-004-005.pdf 
930 |d y  |p y  |q y 
995 |a HumanIndex 
999 |c 777035  |d 777035