ارسل ملاحظاتك

ارسل ملاحظاتك لنا







Modeling Convective Cooling Applied to Perfused and Non Perfused Layers Using Thermal Measurements "With and Without Thermal Capacitance Effects"

المصدر: مجلة العلوم الإنسانية والتطبيقية
الناشر: الجامعة الأسمرية الإسلامية زليتن - كليتى الآداب والعلوم
المؤلف الرئيسي: Al Khwaji, Abd Alsalam (Author)
المجلد/العدد: ع28
محكمة: نعم
الدولة: ليبيا
التاريخ الميلادي: 2016
الشهر: يونيو
الصفحات: 135 - 157
رقم MD: 829446
نوع المحتوى: بحوث ومقالات
اللغة: الإنجليزية
قواعد المعلومات: HumanIndex
مواضيع:
كلمات المؤلف المفتاحية:
Thermal Measurements | Modeling Thermal System | Thermal Capacitance Effect
رابط المحتوى:
صورة الغلاف QR قانون

عدد مرات التحميل

1

حفظ في:
LEADER 02799nam a22002177a 4500
001 1587818
041 |a eng 
044 |b ليبيا 
100 |9 444733  |a Al Khwaji, Abd Alsalam  |e Author 
245 |a Modeling Convective Cooling Applied to Perfused and Non Perfused Layers Using Thermal Measurements "With and Without Thermal Capacitance Effects" 
260 |b الجامعة الأسمرية الإسلامية زليتن - كليتى الآداب والعلوم  |c 2016  |g يونيو 
300 |a 135 - 157 
336 |a بحوث ومقالات  |b Article 
520 |b Thermal measurements are collection of data which are either heat flux or temperature data. Thermal measurements have been used in detecting distribution of heat transfer through the boundary of a thermal system; as an example, the case of modeling burn depth, or skin cancer, etc., where damaged tissue suffers dysfunction perfusion process. Damaged tissue causes blood perfusion either to increase (inflammation process) or decease (burns). In this study, an investigation was carried out to develop an optimal modeling method to simulate heat transfer through a compartment of non-perfused and perfused layers. The first model was one-Layer compartment (thermal resistance model), in which the effect of thermal capacitance of the non-perfused layer was not counted for. The second model was two layer compartment (perfused and non-perfused layers), in which the effect of thermal capacitance of non-perfused layer was included. For the one-layer compartment model, a numerical solution was developed based on finite difference method to describe heat transfer through a perfused layer. This one-layer compartment finite difference solution has perfusion effect and without thermal capacitance effect. The non-perfused layer was represented in the one-layer FD-solution explicitly as thermal resistance. For the two-layer compartment model, another finite difference solution was used to describe the two layers along with the thermal capacitance effect. The results of this investigation demonstrate that by modeling with thermal resistance of a non-perfused layer, the complexity in handling two-layers is going to be reduced, and the estimated parameters of both models was close. 
653 |a القياسات الحرارية  |a السعة الحرارية  |a نمذجة النظم الحرارية 
692 |b Thermal Measurements  |b Modeling Thermal System  |b Thermal Capacitance Effect 
773 |4 العلوم الإنسانية ، متعددة التخصصات  |6 Humanities, Multidisciplinary  |c 032  |l 028  |m ع28  |o 1582  |s مجلة العلوم الإنسانية والتطبيقية  |t Journal of Humanities and Applied Sciences  |v 000 
856 |u 1582-000-028-032.pdf 
930 |d y  |p y  |q n 
995 |a HumanIndex 
999 |c 829446  |d 829446