|a Saeed, Hasan
|e Author
|
245 |
|
|
|a (Comparison of Omani Seismic Code With International Counterparts (UBC 1997 & IBC 2006
|
260 |
|
|
|a مسقط
|c 2015
|
300 |
|
|
|a 1 - 92
|
336 |
|
|
|a رسائل جامعية
|
502 |
|
|
|b رسالة ماجستير
|c جامعة السلطان قابوس
|f كلية الهندسة
|g عمان
|o 0227
|
520 |
|
|
|a Seismic codes represent the guidelines on how simple buildings should be designed to ensure that they can adequately resist seismic force during earthquake. Oman have been working towards preparing its own seismic code for buildings. The code defines the Sultanate to have two seismic zones (Zone 1 and Zone 2). This research focuses on the comparison of this Omani Seismic code (OSC draft version) with International seismic codes (UBC97 and IBC2006) to address the fundamental difference in terms of lateral forces distribution, maximum lateral storey displacement, base shear and bending moments in structural components with three building heights using three different analysis methods. The results have been compared on the basis of international design practice and then based on seismic hazard level. From the design perspective, Muscat, which belongs to Zone-I according to OSC, is defined as Zone-2A in UBC and Zone-II in IBC, while from the seismic hazard perspective it actually is comparable with Zone-1 and Zone-I of UBC and IBC respectively. For all the scenarios (building type and analysis method) investigated, the UBC is found significantly more conservative than OSC & IBC based on International design practice. The values of base shear obtained using UBC97 code are 40 to 70% higher and those from IBC are 30 to 65% more than the value obtained by using the OSC for all buildings. The difference on base shear values between OSC and UBC & IBC decreases as the building height increases. The UBC design response spectra have higher spectral acceleration over the entire period range, and as a result, the response spectrum analysis provides a much higher base shear, displacement and moment in the structural members as compared to IBC and OSC. Similar results pattern is observed in dynamic analysis. Further, comparison between the codes based on seismic hazard, the OSC is found slightly more than UBC & IBC. Finally, a brief comparison is made to do the cost benefit analysis for mostly constructed low rise building under seismic and without seismic design using UBC and OSC code. It is found that the strength and stiffness requirements for OSC is much lower compared with UBC97 currently implemented design practice. Therefore, Omani Seismic Code is preferable and more economical alternative for seismic design of low rise buildings in Oman.
|
653 |
|
|
|a الزلازل
|a سلطنة عمان
|a التجارب الدولية
|a القوانين والتشريعات
|
700 |
|
|
|a Ali, Muhammad Bilal Waris
|e Advisor
|9 523397
|
856 |
|
|
|u 9809-008-006-0227-T.pdf
|y صفحة العنوان
|
856 |
|
|
|u 9809-008-006-0227-A.pdf
|y المستخلص
|
856 |
|
|
|u 9809-008-006-0227-C.pdf
|y قائمة المحتويات
|
856 |
|
|
|u 9809-008-006-0227-F.pdf
|y 24 صفحة الأولى
|
856 |
|
|
|u 9809-008-006-0227-1.pdf
|y 1 الفصل
|
856 |
|
|
|u 9809-008-006-0227-2.pdf
|y 2 الفصل
|
856 |
|
|
|u 9809-008-006-0227-3.pdf
|y 3 الفصل
|
856 |
|
|
|u 9809-008-006-0227-4.pdf
|y 4 الفصل
|
856 |
|
|
|u 9809-008-006-0227-O.pdf
|y الخاتمة
|
856 |
|
|
|u 9809-008-006-0227-R.pdf
|y المصادر والمراجع
|
856 |
|
|
|u 9809-008-006-0227-S.pdf
|y الملاحق
|
930 |
|
|
|d y
|
995 |
|
|
|a Dissertations
|
999 |
|
|
|c 971150
|d 971150
|